Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Energy Storage
Manufacturer/Factory, Group Corporation

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
  • Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
Find Similar Products
  • Overview
  • Product Specification
  • Detailed Photos
  • Application
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
VGG12-165
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Dimension
551*109*287mm
Weight
46.5kg
Design Life
12 Years
Transport Package
Carton+Pallet
Specification
12V165AH
Trademark
Sunstone Power
Origin
China
HS Code
850760
Production Capacity
5, 000, 000 Piece / Month

Product Description

 

Product Specification

 Battery Basic Information

Sunstone VGG Series 12V Front Terminal GEL batteries have special sealed and valve regulated construction. All the acid inside the battery is suspended in a formulated non-woven glass mat separator and it is absorbed in the manner. This construction ensure leakproof during normal operation. There is no need to check or add water or any other specific gravity during the whole service life of the batteries, completely Maintenance Free. The grids are made by heavy duty lead calcium tin alloy. This provides: Safety margin of performance condition, Excellent recovery capacity from deep discharge, Extra service life in either cycle or float application, Low self-discharge when it is not in working.
  
Nominal Voltage 12V (6 cells) Operating Temp.Range Discharge: -15-50°C (5-122°F)
Nominal Capacity 173AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
165AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
140AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
99AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 14.4~14.8V (25°C/77°F) Temp.Coefficient -30mV/°C
Dimension Length 551 ± 2mm Initial Charging Current Less than 50A
Width 109± 2mm Standby Use 13.5~13.8V (25°C/77°F) Temp.Coefficient -20mV/°C
Container Height 287 ± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 287 ± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 46.5Kg 25°C (77°F) 100%
Terminal T3 0°C (32°F) 86%
Container Material ABS Self Discharge VGG series batteries may be stored for up to 6 months
Max. Discharge Current 1600A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx 3.8mΩ For higher temperatures the time interval will be shorter.

Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery

Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery


Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery

Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery
Detailed Photos
Solar Inverter Battery 12V 165ah Front Terminal Telecom BatterySolar Inverter Battery 12V 165ah Front Terminal Telecom BatterySolar Inverter Battery 12V 165ah Front Terminal Telecom BatterySolar Inverter Battery 12V 165ah Front Terminal Telecom Battery
Application


Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery




 

Company Profile

Sunstone Power Co. was established in 2003 in manufacturing, market, and brand-name-building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead supply

areas, we have good advantages in quality control, delivery control, and cost control. So far we are the only factory that gets pollution control

permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt in 2017 and an Indonesian company in Jakarta at the end of 2018.

We have our warehouse in both these two countries. It gives fast delivery and stock support to European and Southeast Asian markets.

Solar Inverter Battery 12V 165ah Front Terminal Telecom BatterySolar Inverter Battery 12V 165ah Front Terminal Telecom Battery


Partners :
Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery

Certifications

Solar Inverter Battery 12V 165ah Front Terminal Telecom Battery

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol) 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier